SiteKiosk: Bug Fix for critical error
On kiosk machines with SiteKiosk versions earlier than 8.7 under Windows 7, the system will in most cases become unusable after Internet Explorer 10 is installed. The affected SiteKiosk versions are 7.1 - 8.6. Any Windows 7 computers that have automatic updates enabled will be affected because Internet Explorer 10 is installed automatically as part of Windows updates.

All software resellers are strongly encouraged to forward this information to the operators of the kiosks. PROVISIO has no information about the end user and therefore cannot directly inform them!

Additional information...
FAQ: Configure print margins for the SiteKiosk Browser
Статья ID: 5796
СтатьяВид статьи: FAQ
Уровень: Закрыто
Платформа: Windows XP Professional
Язык: Английский
Дата создания: 16.08.2007 15:11
Дата последнего изменения: 15.07.2010 10:19
Продукция: SiteKiosk
Версия: -
Просмотров: 9636
Вложение: -
Создано: PROVISIO\olbrich (Provisio)
Изменено: PROVISIO\olbrich (Provisio)
Голосование:
 
Проголосовать
Описание
Since SiteKiosk 7.x the print margins can be configured globally in the SiteKiosk configuration
(-->Management-->Print-->Page Setup)


With older SiteKiosk versions SiteKiosk is just using the margin settings of the IE.
But you have to consider that the margin settings of the IE are user dependent.

To get access to the IE settings in the SiteKiosk user account proceed as follows:

1. Set the System-Security-Manager to "Unprotected"
2. Login as SiteKiosk user (default password "provisio")
3. Check or change your settings
4. Logout
5. Login as Administrator
6. Set the System-Security-Manager to "Protected"
Комментарии (0): Configure print margins for the SiteKiosk Browser