Soporte de pedidos: Script error on loading saved configuration

Descripción

I am receiving several script errors when trying to load an existing configuration file after the initial save. If I delete the old configuration, the Configuration editor will open no problem with a new configuration. Attached are the screenshots, log files, and configuration file. I've tried this on two different systems with the same outcome. Only thing installed is SiteKiosk on these systems. Issue does not appear on an older version of the software - version prior to the December 2018 release.

OS: Windows 10 version 1803
Hardware: HP Compaq Elite 8300 USDT - Intel i7 - SSD with 4GB RAM
Other test system: HP EliteDesk 800 G1 TWR - Intel i5 - SSD with 16GB RAM

Respuesta: (2)

Re: Script error on loading saved configuration 14/05/2019 17:01
I tested your configuration file and found that it could be opened with the following change:

Open your SiteKiosk confguration file in Notepad and search for

<application>C:\windows\SysWOW64\UJSNetwork.scr</application>

then change it to this :

<application></application>
Re: Script error on loading saved configuration 14/05/2019 17:28
That fixed the issue. The program must not like that screensaver. Thank you!